manual s7-200-text-displays 08-2007 en, Instrukcje, SIEMENS KATALOGI, KATALOGI, Katalog 3, chomikuj2

[ Pobierz całość w formacie PDF ]
Preface
S7-200 SIMATIC Text Display (TD) User Manual
1
S7-200
2
SIMATIC
Text Display (TD) User Manual
Using the Keypad Designer
to Create a Custom
Faceplate for your Text
Display (TD) Device
3
System Manual
Using the Text Display
Wizard to Configure the
S7-200 CPU for Your Text
Display (TD) Device
4
5
A
B
C
08/2007
A5E00765548-02
Product Overview
Installing your Text Display
(TD) Device
Operating Your Text Display
(TD) Device
Technical Specifications and
Reference Information
Connecting Multiple Devices
on a Network
Troubleshooting
 Safety Guidelines
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.
CAUTION
without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.
NOTICE
indicates that an unintended result or situation can occur if the corresponding information is not taken into
account.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The device/system may only be set up and used in conjunction with this documentation. Commissioning and
operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes
in this documentation qualified persons are defined as persons who are authorized to commission, ground and
label devices, systems and circuits in accordance with established safety practices and standards.
Prescribed Usage
Note the following:
WARNING
This device may only be used for the applications described in the catalog or the technical description and only
in connection with devices or components from other manufacturers which have been approved or
recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage,
positioning and assembly as well as careful operation and maintenance.
Trademarks
All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this
publication may be trademarks whose use by third parties for their own purposes could violate the rights of the
owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Siemens AG
Automation and Drives
Postfach 48 48
90327 NÜRNBERG
GERMANY
A5E00765548-02
Ⓟ 02/2008
Copyright © Siemens AG 2007.
Technical data subject to change
Safety Guidelines
Preface
Scope of this Manual
This manual describes the installation, configuration and operation of the TD 100C version
1.0, the TD 200 version 3.0, the TD 200C version 1.0, and the TD400C version 2.0. This
manual also describes the Text Display wizard of STEP 7-Micro/WIN (used to configure the
S7-200 CPU for the TD devices) and the Keypad Designer application (used to configure the
keypad of the TD 100C, the TD 200C and the TD400C).
To utilize these TD devices, you must use the following:

STEP 7-Micro/WIN version 4.0 SP2 or greater for TD 100C version 1.0

STEP 7-Micro/WIN version 4.0 or greater for TD 200C version 1.0 and TD 200
version 3.0

STEP 7-Micro/WIN version 4.0 SP6 or greater for the TD400C version 2.0
Purpose of the manual
The SIMATIC Text Display (TD) User Manual is a combination user and reference manual
that describes the operation of the TD devices with an S7-200 CPU.
Required Basic Knowledge
This manual is designed for engineers, programmers, and maintenance personnel who have
a general knowledge of programmable logic controllers and operator interfaces.
Recycling and Disposal
Please contact a company certified in the disposal of electronic scrap for environmentally
safe recycling and disposal of your device.
Place of this Document in the Information Environment
Table 1 Place of the Text Display User Manual in the Information Environment
Product Family Documentation
Order Number
S7-200
SIMATIC Text Display (TD) User Manual (resides on
the STEP 7-Micro/WIN documentation CD)
Not applicable
Simplified Chinese Character Set (resides on the
STEP 7-Micro/WIN documentation CD)
Not applicable
S7-200
S7-200 Programmable Controller System Manual 6ES7 298-8FA24-8BH0
Text Display (TD) User Manual
System Manual, 08/2007, A5E00765548-02
3
 Preface
Finding Your Way
If you are a first-time (novice) user of TD devices, you should read the entire SIMATIC Text
Display (TD) User Manual. If you are an experienced user, refer to the table of contents or
index to find specific information.
The SIMATIC Text Display User Manual is organized according to the following topics:

Chapter 1 (Product Overview) provides an overview of the TD devices

Chapter 2 (Installing Your TD Device) provides installation instructions and guidelines.

Chapter 3 (Using the Keypad Designer to Create a Custom Faceplate for Your TD
Device) provides information about the Keypad Designer and the steps required for
configuring the keypad and faceplate for the TD devices that can be customized..

Chapter 4 (Using the Text Display Wizard to Configure the S7-200 CPU for Your TD
Device) provides information about using the Text Display wizard of STEP 7-Micro/WIN to
configure the S7-200 CPU for the TD device.

Chapter 5 (Operating Your TD Device) provides information about the basic operation of
the TD devices and also describes the features and capabilities.

Appendix A (Technical Specifications and Reference Information) provides the technical
information for the TD devices and also provides references for the character sets
supported.

Appendix B (Connecting Multiple Devices on a Network) provides information about using
a TD device in a network with other TD devices and S7-200 CPUs.

Appendix C (Troubleshooting) provides information to help you diagnose problems with
the TD device.
The Simplified Chinese Character Set shows the characters supported by the TD devices.
This file is an electronic file and resides on the STEP 7-Micro/WIN documentation CD.
Approvals
Agency Approvals
The SIMATIC Text Display (TD) devices meet the standards and regulations of the following
agencies.

Underwriters Laboratories, Inc. (UL): UL 60950 for the TD 200C and TD 200; and UL
508, UL 1604 for the TD 100C and TD400C

Canadian Standards Association: CSA C22.2 No. 60950 standard for the TD 200C and
TD 200; and CS22.2 No. 142 standard and CSA-213 for the TD 100C and TD400C
Refer to Appendix A for additional compliance information.
Text Display (TD) User Manual
4
System Manual, 08/2007, A5E00765548-02
 Preface
Certification
The SIMATIC Text Display devices have the following certifications:

Underwriters Laboratories (UL) Standards

TD 200C and TD 200: UL 60950 and CSA C22.2 No. 60950

TD 100C and TD400C: UL 508 and CS22.2 No. 142; UL 1604 and CSA-213

Factory Mutual Research: Standard Class Number 3611, Class I, Division 2, Group A, B,
C, D, and Class I, Zone 2, Group IIC.
Temperature class T5 is adhered to when the ambient temperature during operation does
not exceed 60 degrees C.
CE Labeling
The SIMATIC TD devices fulfil the requirements and protection guidelines of the following
EU directives:

EC Directive 94/9/EC "ATEX directive" (TD 200 and TD 200C only)

EC Directive 89/336/EEC "EMC directive" (TD 100C, TD 200, TD 200C and TD400C)
C-Tick
The SIMATIC devices are compliant with requirements of the following standards.

AS/NZS CISPR22 (TD 100C, TD 200, TD 200C)

AS/NZS CISPR11 (TD400C)
Note
The only valid approvals for the TD400C device are those shown on the label on the rear
panel of the device.
Services and Support
Additional Support
Local Siemens Sales Office or Distributor: For assistance in answering any technical
questions, for training on the S7-200 products, or for ordering S7-200 products, contact your
Siemens distributor or sales office. Because your sales representatives are technically
trained and have the most specific knowledge about your operations, process and industry,
as well as about the individual Siemens products that you are using, they can provide the
fastest and most efficient answers to any problems that you might encounter.
Text Display (TD) User Manual
System Manual, 08/2007, A5E00765548-02
5
  [ Pobierz całość w formacie PDF ]